5 - 3 Handling during operation
(1) Checking after startup
Ф Make sure that each m eter and lamp are normal.
normal : warning lamp is all off
®
Make sure that the color of exhaust gases from the engine is normal.
Check for unusual noise and vibration.
Color of exhaust gases
- Colorless or light blue: Normal
— Black: Abnormal, incomplete combustion
— White: Abnormal, combustion of oil due to failure of oil
-
42
-