![Denyo DCA-25USI Instruction Manual Download Page 41](http://html1.mh-extra.com/html/denyo/dca-25usi/dca-25usi_instruction-manual_2485064041.webp)
Д CAUTION
* Do not start the engine when the machine and the load circuit breaker are ON, or else,
power is supplied to the load at the start of the engine which causes electric shocks or
trouble in the load.
Startup procedure:
(1) The 25USI unit is equipped with a fuel cock at the
bottom of the fuel tank.
Turn the cock downward to
open the halve before starting engine.
(2) Make sure that the circuit breakers of
the machine and the loads are all OFF.
(3) Set the throttle lever in the "START /
IDLING" position.
(4) Set the starter switch in "Preheat"
position. This switch m ust be ON until
the preheat lamp becomes red heated. *
Turn the starter switch to "START"
position until engine starts.
[Note]
If the engine is warm, the preheat
operarion is not required.
*In the case of 25USMJSI2 and 45USI*
USI2, turn the starter switch to "START"
position after the going OFF of the
preheat lamp at the "RUN" position
of the starter switch.
The duration of preheating differs
according to the temperature of
cooling water. And if the temperature
of cooling water is high enough, the
preheat lamp does not light because
no preheating is required.
r
"\
\ b
Fuel tank
n
|
\
4
V \ \ v
,-U CLOSE
r
J
T OPEN
V
J
-
40
-