Page 24
CAUTION!
Risk of damage to electronic controller
components due to arcing!
During the heating phase, if the space between
metallic objects and the walls of the heating
chamber is too small, there is a risk of electrical
discharges. This may cause irreparable damage to
the control electronics of the furnace.
Therefore:
Ensure that metal objects do not touch the
walls of the heating chamber.
7.2 Turning on the furnace
Turn on the main power switch.
The power indicator in the power switch will be lit.
After a few seconds, the display will show the standby screen
with the same heating program loaded as when the unit was last
turned off.
If the unit is to be used for the first time, this will be program 01.
Fig. 13:
Standby screen.
The display is structured as follows:
Parameters, level 4
Status (READY), program no (01)
Parameters, level 3
Furnace temperature (current)
Parameters, level 2
Weekday, time (current)
Parameters, level 1
Expected time of completion