Page 31
Fig. 30: Entering the holding time.
4
.
Enter the holding time via the numeric keypad.
Note:
Maximum holding time:
240 minutes.
After all three heating parameters have been defined, the settings
for one heating level are complete.
Additional heating levels
The
S2
to
S4
buttons can be used to define up to three additional
heating levels. To do so, repeat steps 1 to 4 for the additional
levels.
Note:
Make sure that the heating parameters for all
levels that are not defined are set to “0”.
If level 4 (
S4
) was defined as the last heating level,
a valid temperature must be entered for this level.
7.8 Saving a heating program
The controller can store up to 30 different heating programs.
Note:
The controller will always save the heating program
under the same number for which it had previously
been loaded.
Heating programs are retained even after turning
off the furnace.
Fig. 31: Save dialogue.
1
.
Press the
Save
button.
The display shows the save dialogue.
2
.
Press the
S2
button to save or
3
.
Press the
S1
button to cancel.
After confirming or cancelling the save operation, the display
returns to the standby screen.
Entering a comment
To clearly identify a program, each heating program can be
assigned a comment that may consist of up to 4 lines of 11
characters. This facilitates identification of the desired heating
program if a large number of heating programs exists.