Dentsply Sirona digit Power Operation Manual Download Page 1

Caution: For dental use only.
U.S.A.: Rx only.

1. PRODUCT DESCRIPTION

The digit power

Dispenser consists of a dispensing handpiece, with an air supply tube connected to

an adjustable pressure regulator. The regulator can be connected to an existing standard ISO 4-hole,
5-hole or 6-pin air supply line, or if equipped, to a MIDWEST

®

Stylus

/XGT, StarDental HiFlo

®

or KaVo

MULTIflex

®

coupler. The adapter allows airline activation using the standard foot pedal for control of

the Dispenser. The adapter is adjustable, providing fit to most commonly used delivery systems and
tool pockets.

1.1 Delivery forms*

The digit power

Regulator is available with the following airline connections:

• ISO Threaded Connector 

(compatible with ISO 4-hole, 5-hole fiber optic, and 6-pin dental hoses)

• MIDWEST

®

Insert female quick-connect/disconnect 

(compatible with MIDWEST

®

Stylus

and XGT couplers)

• StarDental HiFlo

®

Insert female quick-connect/disconnect 

(compatible with StarDental HiFlo

®

Swivel Connectors)

• KaVo MULTIflex

®

Insert female quick-connect/disconnect 

(compatible with KaVo MULTIflex

®

coupler)

1.2 Indications

The digit power

Dispenser is indicated for intraoral delivery of materials provided in the 

digit power

cartridges.

1.3 Contraindications

None known.

2. GENERAL SAFETY NOTES

Be aware of the following general safety notes.

2.1 Warnings

None known.

2.2 Precautions

• Wear suitable protective eyewear, mask, clothing and gloves. Protective eyewear is recommended for patients.
• digit power

Dispenser regulator is designed for input pressures of 60 to 80 psi. Lower input pressures may affect output pressure and material dispensing rate.

• Improper alignment of the notches on the cap and grip after loading a cartridge can result in a device malfunction.
• Always put the digit power

Dispenser in the adapter with the dispensing end up to prevent clogging.

• Do not autoclave the digit power

Dispenser body, tubing or regulator.

• Do not immerse the digit power

Dispenser in water or disinfectant. Do not spray liquids directly into the Dispenser. Spray a towel, then wipe the Dispenser. 

Prevent liquids from entering openings on the Dispenser.

• If plungers do not retract after releasing foot pedal, allow cartridge to empty away from patient field, disconnect unit and return for service. 

Do not attempt to disassemble or use further.

• Do not use the digit power

Dispenser with Aquasil Ultra Material XLV, LV and Regisil Rigid in digit

®

Targeted Delivery System cartridges. 

Device and cartridge malfunction may occur.

2.3 Adverse reactions

None known.

2.4 Storage conditions

Inadequate storage conditions may shorten the shelf life and may lead to malfunction of the product.
• Store at temperatures between 10ºC/50ºF - 24°C/75°F. 
• Use the product at room temperature. 
• Do not store used cartridges with new (unused) mixing tips attached.
• Do not freeze. 
• Protect from moisture. 
• Do not use after expiration date.

digit power

Dispenser

OPERATION MANUAL – ENGLISH

4-hole

5-hole

6-pin

Cap

Grip

Adapter

Dispenser

Regulator

Push
Fitting

Push
Fitting

Threaded
Ring

Connector
(regulator
type varies)

Speed Control Knob

Adapter

Post

Adapter

Adjustable

Arm Screw

Adapter

Adjustable

Arm

Speed Indicator

Speed Settings

Air Supply Hose

Alignment
Notch

Summary of Contents for digit Power

Page 1: ...d for input pressures of 60 to 80 psi Lower input pressures may affect output pressure and material dispensing rate Improper alignment of the notches on the cap and grip after loading a cartridge can...

Page 2: ...ridge into mixing tip Ensure both cartridge spurs fully lock into the square holes on the side of the mixing tip Use only the provided digit power mixing tips Remove the Cap from the Dispenser and ins...

Page 3: ...que tip Use your thumb and index finger to hold the push fitting down tightly while pulling the hose in the other direction Step 2 The new air hose can be cut to length with scissors if desired Step 3...

Page 4: ...into the bottom of the regulator using caution to avoid cross threading the parts Turn clockwise to install Step 6 Tighten the coupler insert using the 5 32 hex key Turn clockwise to tighten ORDERING...

Page 5: ...si Las presiones de entrada m s bajas pueden afectar la presi n de saluda y la velocidad de suministro del material Una alineaci n indebida de las muescas en la tapa y la empu adura luego de cargar el...

Page 6: ...r para usar desencajando el disco circular del cartucho Inserte el cartucho de dosis unitaria en la punta de mezcla Aseg rese de que ambos espolones del cartucho est n completamente trabados en los or...

Page 7: ...or mientras tira de la manguera Consejo t cnico Use el pulgar y el dedo ndice para presionar firmemente el racor mientras tira de la manguera hacia el sentido opuesto Paso 2 La manguera de aire nueva...

Page 8: ...r que desee en el fondo del regulador cuidadosamente para evitar enroscar las piezas en forma cruzada Gire hacia la derecha para instalar Paso 6 Ajuste el inserto del acoplador con una llave hexagonal...

Page 9: ...mauvais alignement des encoches sur le capuchon et la poign e apr s le chargement de la cartouche peut causer un mauvais fonctionnement de l appareil Il est important de toujours placer le distribute...

Page 10: ...ur Assurez vous que les deux perons de la cartouche se verrouillent dans les trous carr s sur le c t de l embout m langeur Utilisez uniquement les embouts de m lange digit power inclus Retirez le capu...

Page 11: ...pouce et votre index pour tenir le raccord instantan enfonc pendant que vous tirez la conduite dans l autre sens tape 2 Si vous le d sirez la nouvelle conduite peut tre coup e la longueur de votre ch...

Page 12: ...nsert de coupleur de votre choix dans le bas du r gulateur en faisant attention de ne pas croiser les filetages des pi ces Tournez la pi ce dans le sens horaire pour l installer tape 6 Serrez l insert...

Reviews: