11.5
Selectable Scanning Methods
Data output timing and outputs can be set for each scanning mode as shown below.
Scanning mode
Data output
timing
Non-scan code
OK signal
NG signal
Synchronous mode
Enabled
Enabled
Enabled
Trigger mode
Asynchronous mode
Enabled
Enabled
Enabled
Continuous reading mode
A/B
Asynchronous mode
Disabled
Enabled
Disabled
Auto sense
Asynchronous mode
Disabled
Disabled
Disabled
Scanning mode
Verification OK
Verification NG
Enabled Enabled
Trigger mode
Enabled Enabled
Continuous reading
mode A/B
Enabled Enabled
Auto sense
Disabled
Disabled
11.6
SHT Signal (External Lighting Synchronous Output Signal)
The scanner output the SHT signal that synchronize to the exposure operation of the scanner from the output terminal 2
when the output terminal 2 is set in the SHT signal. Polar character of the SHT signal can be selected from the
following two types using the commands or configuration software.
Signal polarity
During Exposure
Except during exposure
Tr ON
HIGH
LOW
Tr OFF
LOW
HIGH
Note:
1. Some external lights which will take time for start-up, for example a halogen lamp, may not respond quickly or light up
properly. You are required to use a light, such as a LED, with a faster response.
2. The output terminal 2 output is a NPN open collector and power shall not be supplied from the terminal. Do not apply
power exceeding the specified voltage level to the output terminal 2. It may cause the scanner to break or malfunction.
49
Summary of Contents for QB30-SR
Page 1: ...2D Code Scanner Fixed type QB30 SR QB30 SU User s Manual...
Page 112: ...Terminator when transmitting None ETX CR LF CR LF 101...
Page 114: ...USB interface to the host USB COM interface default USB keyboard interface 103...
Page 123: ...Beeper control Disable Enable default Indicator LED Disable Enable default 112...