36
7.2.3 Data blocksorting mode
The scanner splits code data read into a maximum of 5 blocks at the specified split positions, sorts those blocks in the
specified order, and outputs it in the data transmission format selected in the scanner (see Chapter 9, Section 9.4).
Note:
The split position must be specified by the number of digits from the head of code data read. Specifying the
number of digits exceeding that in the code data results in an error.
Blocksorting conditions
Blocksorting conditions
Choices
Any code
QR Code
PDF417
Data Matrix
MaxiCode
UPC-A/EAN-13
UPC-E
EAN-8
Code 128
EAN-128 (GS1-128)
Codabar (NW-7)
Code 39
Code 93
Interleaved 2of5 (ITF)
RSS (GS1 DataBar)
"Code type"
EAN.UCC Composite symbology
Example Code read: Code 128, Data: 1234567890,
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: 4 digits, Prefix/Suffix: None, BCC: Disable
Split position
Order of blocks
Output data
3rd position, 8th position
Block 2, 1, 3
[STX]K00104567812390[ETX]
3rd position, 8th position
Block 1, 3
[STX]K000512390[ETX]