(3) Bar Code Label Size
Recommended width:
10 mm min. (0.39 inch min.)
Depth of field
(Distance from bar codes to the
reading window)
Length of labels
(including margins)
Length:
400 mm (15.7 inches)
200 mm max. (7.87 inches max.)
(Minimum narrow bar width: 0.635 mm min.)*
6
(4) Thickness of Bars and Depth of Field
Minimum narrow bar width
Depth of field
0.125 mm (4.92 mils)
0.15 mm
(5.91 mils)
0.19 mm
(7.48 mils)
0.25 mm
(9.84 mils)
0.33 mm (12.99 mils)
0.50 mm (19.69 mils)
0.635 mm (25.00 mils)
1.00 mm (39.37 mils)
16 to 75 mm (0.63 to 2.95 inches)
*1
5 to 105 mm (0.20 to 4.13 inches)
*2
5 to 135 mm (0.20 to 5.31 inches)
*3
5 to 190 mm (0.20 to 7.48 inches)
*4
0 to 310 mm
(0 to 12.20 inches)
*5
0 to 420 mm
(0 to 16.54 inches)
*6
0 to 470 mm
(0 to 18.5 inches)
*7
70 to 620 mm (2.76 to 24.41 inches)
*8
*
1
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- Code 39, 19 digits
Narrow bar: Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
*
5
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- Code 39, 20-digit
Narrow bar : Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
*
2
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- Code 39, 14-digit
Narrow bar : Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
*
6
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- Code 39, 15-digit
Narrow bar : Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
*
3
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- Code 39, 5-digit
Narrow bar : Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
*
7
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- ITF conforming to the UPC Shipping Container Code
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
-
0.625
magnification
*
4
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
- Code 39, 20-digit
Narrow bar : Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
*
8
Under the following conditions:
- Ambient illuminance: 500 lx. (Xenon arc lamp)
-
ITF conforming to the UPC Shipping Container Code
Narrow bar : Wide bar = 1 : 2.2
- Reflection intensity of white bars: 85% min.
Reflection intensity of black bars: 5% max.
-
1.0
magnification
152
Summary of Contents for 400BW-CE
Page 1: ...Bar Code Handy Terminal BHT 400B CE 400BW CE User sManual ...
Page 20: ......
Page 34: ...14 ...
Page 152: ...132 ...