6. Inspection prior to operation
Attention!
Fix the generator with the fixing brake at the wheel.
1. Connecting the battery
Advice:
After a longer storage it is necessary to charge the battery completely. Otherwise it is only
possible to start the generator with the recoil starter.
Open the battery compartment with the help of a screwdriver and combine the two white plug
connectors. Ensure the correct polarity!
2. Check the oil level of the engine
Attention!
The generator is delivered without oil. Please pay attention to the following advices for the choice of
the oil.
The motor oil has great influence on the lifetime and performance of the engine. Two-stroke oils may
damage the engine and are therefore not recommended.
Use a four-stroke oil that fulfils or exceeds the requirement of the API-classification SL. Always check
the APISERVICE-label on the oil container for the letters SL.
We recommend SAE 10W-30 for daily use for all temperatures, better SAE 10W40.
Loosen the screw on the left side panelling, and take off the cover.