0
Get
ting Star
ted
Connections
Set
up
Pla
ybac
k
Remot
e Contr
ol
Multi-Zone
Inf
or
mation
Tr
oubleshooting
ENGLISH
Auto Setup
Optimize settings for speakers in use.
Step 2 : Measurement
q
Press
i
to select “2nd Start”, then press
o
.
• Measures the 2nd measurement position.
w
Move the microphone to the 3rd point and press
o
.
• Measures the 3rd measurement position.
e
Perform
w
repeatedly.
• To measure the remaining measurement positions.
Get
ting Star
ted
Connections
Set
up
Pla
ybac
k
Remot
e Contr
ol
Multi-Zone
Inf
or
mation
Tr
oubleshooting
a
Auto Setup
The settings found at this stage are applied automatically.
G
Auto setup fl ow
H
Step1:
Speaker Detection
Step2:
Measurement
Step3:
Calculation
Step4:
Check
Step5:
Store
Start
Press
o
to start the MultEQ Auto Setup.
The Audyssey MultEQ Auto Setup process automatically calculates
the size, level, distance, bass management crossover frequency, and
optimal settings for each speaker and subwoofer. Audyssey MultEQ
corrects acoustical distortions within the listening area.
Before starting, connect and position all your speakers.
Once started, MultEQ will play a series of test tones through each
speaker.
If an error message appears during the measurements, check “Error
Messages”, take the advised action, then start the measurements
again (
v
page 21).
The speaker connection and polarity are detected at the fi rst
measurement position. The following attributes are also determined
at this time: “Speaker Size”, “Speaker Distance”, “Channel Level”,
“Crossover Frequency”.
Once the measurements are completed, “Sp Detect Check” is
displayed.
Press
ENTER
to check the results of the speaker detection.
Example :
7.1-channel systems
S p e a k e r : 3 / 4 / . 1
Step 1 : Speaker Detection
NOTE
• Loud test sounds may be played during Audyssey MultEQ Automatic
Speaker Setup. This is part of normal operation. If there is background
noise in room, these test signals will increase in volume.
• Do not stand between the speakers and setup microphone or allow
obstacles in the path while the measurements are being made. This
will cause inaccurate readings.
• Quiet the listening environment before beginning measurements and
refrain from talking. Turn off air conditioning units or other devices
that emit noise if at all possible as measurements may be affected
by these sounds.
• Operating
MASTER VOLUME
during the measurements will cancel
the measurements
.
• Do not change the speaker connections or subwoofer volume after
“Step 1”.
• If the results are not as expected or if an error message is displayed,
address any error as required, select “Retry” and perform the
measurement again.
• If the results of measurement are still not as expected or an error
message is displayed, turn off the power switch and check the
speaker connections. Then start measurements again from the
beginning.
After completing a measurement position, move the microphone to
the next position.
Measure at 6 positions: the main listening position and 5 other
surrounding positions. Although it is allowable to measure less than 6
positions, it is recommended to measure
6
for best results.
Subwoofer
Surround and Surround
back speakers
Front and Center speakers
NOTE
• Do not disconnect the setup microphone until the auto setup
procedure is completed.
• When using headphones, unplug the headphones before starting
the auto setup procedure.
When using a subwoofer, make the following settings before starting
the auto setup procedure:
• Defeat the volume and crossover controls if possible
• If this is not possible then set:
•
Volume: “12 o’clock” position
•
Crossover frequency: “Maximum/Highest Frequency”
•
Low pass fi lter: “Off”
•
Standby mode: “Off”