Get
ting Star
ted
Connections
Set
up
Pla
ybac
k
Remot
e Contr
ol
Multi-Zone
Inf
or
mation
Tr
oubleshooting
ENGLISH
Symptom
Cause
Countermeasure
Page
No sound is
produced from
center speaker.
• You are playing a monaural
source (TV, AM radio broadcast,
etc.) in the “STANDARD” (Dolby/
DTS Surround) mode.
• The mode is set to something
other than “STANDARD” (Dolby/
DTS Surround).
30
No sound
is produced
from surround
speakers.
• The surround mode is set to
“STEREO” or “DIRECT”.
• Set to a surround playback
mode.
30
No sound is
produced from
surround back
speaker.
• The surround back speaker’s
power amplifier is assigned to a
different channel.
• Surround back speaker setting is
set to “None”.
• Surround mode not set to a mode
for 6.1- or 7.1-channel playback.
• Check the setting and change it
as necessary.
• Set to something other than
“None”.
• Select a surround playback
mode.
27
23
29, 30
No sound is
produced from
subwoofer.
• Subwoofer’s power not turned
on.
• The “Subwoofer” setting at
“Speaker Setup” is set to “No”.
• The subwoofer is not properly
connected.
• The subwoofer’s volume is
turned off.
• Turn on the subwoofer’s power.
• Set to “Yes”.
• Check the connections.
• Adjust the subwoofer’s volume
to an appropriate level.
–
23
9
41
No test tones are
produced when
remote control
unit’s
TEST
button
is pressed.
• Surround mode not set to
“STANDARD”
(Dolby/DTS
Surround).
• Set to the “STANDARD” (Dolby/
DTS Surround) mode.
29
DTS sound is not
output.
• DVD player’s audio output setting
is not set to bitstream.
• DVD player is not compatible
with DTS sound playback.
• The AVR-688’s “Input Mode”
setting is set to other than
“DTS”.
• Set the DVD player. For details,
refer to the DVD player’s
operating instructions.
• Use a DTS-compatible player.
• Set to the “Auto” or “DTS”
mode.
–
–
35
HDMI audio
signals are not
output from
speakers.
–
• The audio signal input to the
HDMI input connector cannot be
played on the AVR-688. Input the
audio signal to the digital audio
input connector or analog audio
input connector.
10
No sound is
output from
the monitor
connected
with HDMI
connections.
• HDMI input setting is improper.
• Check the HDMI input setting.
25
G
Audio
H
Symptom
Cause
Countermeasure
Page
No picture
appears.
• The connections between the
AVR-688 and monitor are faulty.
• The monitor’s input setting is
wrong.
• The player is connected using the
component input connectors, the
monitor is connected using the
video (yellow) or S-Video output
connectors.
• Check the connections.
• Set properly.
• High definition (1080i/720p) and
progressive (480p/576p) video
signals are not down-converted.
Set the player to interlace
(480i/576i) signals.
10 ~ 17
–
–
No picture
appears
with HDMI
connections.
• The connections to the HDMI
connectors are faulty.
• HDMI input setting is improper.
• The HDMI format of the player
and monitor do not match.
• Check the connections.
• Check the HDMI input setting.
• Match the HDMI format of the
player and monitor.
10
25
10
Picture cannot be
recorded.
• Input source does not match
recorder’s video connection
connector (video or S-Video).
• The video conversion function
does not work for the REC
OUT connectors. Match the
input source and recorder
connections.
13
DVDs cannot be
copied on a VCR.
–
• This is not a malfunction. Most
movie software includes copy
prevention signals and cannot be
copied.
–
G
Video
H
Tr