PCI-DMC-A01/B01 User Guide
Chapter 3 Using EzDMC
3-8
July 2014
As shown in Figure 3.10, the multi-axis control window can be divided into the four following
blocks and functions.
Figure 3.10
First block: Select the motion status display, position reset and motor excite function. Only
3-axis motion control is available at the moment.
Second block: Each motion parameter that must be set for motion operation; these settings
are linked with the selections in the "Third block: Motion operating mode
settings."
Third block: Motion operating mode settings. The 6 motion control commands available
include 2-axis linear interpolation, 3-axis linear interpolation, 2-axis arc
interpolation and 3-axis helical.
Fourth block: Execute motion commands such as clockwise rotation, CCW rotation and
stop.
Check "Repeat" to repeatedly execute clockwise and CCW motion.
Check "S Curve" to set acceleration/deceleration as S-curve. The T-curve
will be used otherwise.
Check "Abs" to use absolute motion. Relative motion will be used
otherwise.
Block 2
Block 1
Block 3
Block 4