9.6.4.5 Data Mapping
In the Controller Organizer, you can map data, including Configuration, Input and Output parameters. When you create a
device I/O Configuration, the tags are added automatically.
Click
Program TAGs
to display the Tags window.
Tags are listed in the
Name
column. Tag names begin with a product name and end with
C
or
I1
or
O1
, separated
from the name by a colon (:), for example CMCEIP01:C, CMCEIP01:I1, and CMCEIP01:O1.
Tag name
:
C indicates the tag contains information from the Adapter EDS file, including Input and Output
parameters. You can edit these parameters in Studio 5000.
Tag name
:
I1 indicates that the mapping starts from TAG
:
I1[0], and is mapped to the first parameters of the
Adapter output. The length is the output length provided by the Adapter.
Tag name: O1, indicates that the mapping starts from TAG
:
O1[0], and is mapped to the first parameters of the
Adapter Input. The length is the input length provided by the Adapter.
Tag:I1[0]
Tag:I1
Tag:I1[1]
Tag:I1[31]
Parameter_0
Parameter_1
Parameter_31
Adapter
Output
Tag:O1[0]
Tag:O1
Tag:O1[1]
Tag:O1[31]
Parameter_0
Parameter_1
Parameter_31
Adapter
Input
Delta Adapter
VFD-C2000
RA EIP Scanner
1756-L71+1756-EN2TR
EtherNet/IP
..
.
..
.
..
.
..
.