20
enters into the cylinder intensity setting
, LED display flashes and displays
, and at the same time, LED indicator SET is lit up; then, use UP or DN
key to adjust the intensity setting value (system default intensity setting value is 01,
and the setting range is 01 ~ 10, 5v ~ 10v for a total of 10 levels, and 0.5v per level).
After 3S without pressing any keys or other key is pressed within 3S, the system
confirms the setting is complete and a buzzer is sounded as an indication of the
completion.
1-8. Under the standby or operation state,
press the SET key the tenth time, the system
enters horizontal conveying motor delay setting (the delay time after retrieving
screws completely)
, LED display flashes and displays
, and at the same
time, LED indicator SET is lit up; then, use UP or DN key to adjust the delay time
setting value (system default delay time value is 01 (300ms), and the setting range is
01 ~ 08 (300ms - 2.4s)). After 3S without pressing any keys or other key is pressed
within 3S, the system confirms the setting is complete and a buzzer is sounded as an
indication of the completion.
1-9. Under the standby or operation state,
press the SET key the eleventh time, the
system enters horizontal conveying motor speed setting
, LED display flashes and
displays
, and at the same time, LED indicator SET is lit up; then, use UP
or DN key to adjust the speed setting value (system default speed value is 01, and the
setting range is 01 ~ 10). After 3S without pressing any keys or other key is pressed
within 3S, the system confirms the setting is complete and a buzzer is sounded as an
indication of the completion.
1-10. Under the standby or operation state,
press the SET key the twelfth time, the system
enters into the vibration direction forward and reverse rotation setting
, LED
display flashes and displays
, and at the same time, LED indicator SET is
lit up, wherein 00 refers to the forward direction method, and 01 refers to the reverse
direction method; press Up or DN to toggle for adjustment (system default method is
00). After 3S without pressing any keys or other key is pressed within 3S, the system
confirms the setting is complete and a buzzer is sounded as an indication of the
completion. Such loop repeats for operation.
2. Under the power-off state of the system, the count value set and the work state before
power-off are memorized.
3. Under the standby or operation state, press the UP key and the DOWN key together for 3S,
the count total number is displayed and a buzzer is sounded; after 5S or press the OK key to
return to the current state. During the display of the count total number, press the SET key to
clear the count total number to zero and a buzzer is sounded; after 5S or press the OK key to
return to the current state.
4. When the system count reaches the alarm count value, the buzzer is sounded and the LED
indicator COUNTER flashes; press SET to cancel the alarm.
5. Under the standby or operation state, press the SET key and OK key together for 3S, the
system returns to the factory setting value and a buzzer is sounded; after the LED screen and
indicator flashes at 1Hz for 3S, a buzzer is sounded.