BECT832-SSO Screwdriver Controller
Operation Manual
DELTA REGIS
Tools Inc.
DIP Switch Settings
www.deltaregis.com
There is a 7-position DIP Switch mounted in the rear face of the controller,
next to the I/O Connector. The controller is shipped from the factory with all
switches in the OFF (down) position. Please refer to the following guide to
select the proper switch positions to suit your specific application.
SW 1 - Counting Method
Determines whether the controller counts up from zero to the programmed batch value, or
counts down from the batch value to zero. OFF = Count Down, ON = Count Up
SW 2 - External Switch (GATE Input)
If the process requires that an external input signal be present (at the GATE input) to allow the
screwdriver to enable to start a new batch, then SW2 must be in the ON position. When SW2 is OFF,
the external GATE input signal is not required. Refer to the diagrams below (SW 4 description) for
further details on input signals and signal logic.
SW 3 - Manual or External Confirm to Reset Batch
With SW3 in the OFF position, the controller automatically resets to begin a new counting
batch after completion of the previous batch. Placing SW3 in the ON position will require the operator
to press the SELECT button (or require an external CONFIRM input) at the end of each batch before
the controller will reset to run a new batch. Upon batch completion, the display will flash ‘C3’ and the
screwdriver will be disabled until the SELECT button is pressed (or a CONFIRM signal is input).
SW 4 - Multiple External Switch Inputs (GATE Input)
In some instances, it may be desireable to interface two external input switches wired in
parallel to the GATE input. As an example, one switch might be triggered by a finished part leaving the
assembly station while the other is triggered by a new part entering the station. With SW4 in the OFF
position (and SW2 ON), one external switch signal is required to enable the screwdriver. With SW4 in
the ON position (and SW2 ON), two external switch signals are required to enable the driver.
OFF
ON
Last batch
completed
Batch resets,
driver enabled
Input
Signal
Waiting for input,
driver disabled.
Display flashes ‘C1’
External Switch
(GATE Input)
1 External Signal at GATE Input
(DIP SW2 on / SW4 off)
OFF
ON
Last batch
completed
Batch resets,
driver enabled
Input
Signal 1
Waiting for input,
driver disabled.
Display flashes ‘C2’
External Switch
(GATE Input)
Input
Signal 2
2 External Signals at GATE Input
(DIP SW2 on / SW4 on)