BECT832-SSO Screwdriver Controller
Operation Manual
DELTA REGIS
Tools Inc.
www.deltaregis.com
Input / Output Connector
An input/output connector is provided on the
back face of the controller for interfacing signals
with external equipment.
V+
DC voltage (+24VDC, 200mA max) available if
required to power external circuits
OK
Closes an output contact when an acceptable
(GOOD) rundown cycle is completed
NG
Closes an output contact when an unacceptable
(NG) rundown cycle occurs
OK ALL
Closes an output contact when the batch is
completed
COM
Common (0VDC) - used when wiring in external
input switches, or in conjunction with V+ supply
ENABLE
Input for external switch(es) verifying that the
driver can be enabled to begin a new batch.
The
use of external switches is dependent on DIP
Switch Settings. Please see next page.
CLEAR
Input for external resetting of the batch count
CONFIRM
Input for external confirmation that the process
can continue
(see DIP SW3 description)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Page 11
Output Terminals
OUTPUT TERMINALS 2 thru 7
Connection pairs 2/3, 4/5 and 6/7 are dry relay
contact outputs (AC/DC 40V, 250mA max).
INPUT TERMINALS 8 thru 13, COM 14
Connect an external switch between COM
(terminal 14) and the input terminal (8-13). Use
a separate switch contact for each required
input. Closing the contact will activate the input.
DO NOT SUPPLY POWER TO INPUTS.
Input Terminals
V+ (24VDC, 200mA max)
START input
REVERSE input
DISABLE input
CONFIRM input
ENABLE input
CLEAR input
OK output
NG output
OK ALL output
COM (0VDC)
connect each
req’d input
through a dry
switch contact
to COM (14).
MOS relay
outputs -
40V, 250mA
maximum
OFF
ON
DISABLE
Input to externally disable the screwdriver
between rundowns as required by the process.
START and REVERSE
The reverse input works in conjunction with
the start input. Providing a START input signal
will remotely start the screwdriver; providing a
REVERSE input signal prior to the START input
will start the tool in reverse.
OFF
ON