The Limit Status or LIM-status is "1" in case the output 
voltage or current reaches the limit setting. Which limit circuit 
is active can be seen on the front panel indicators. 

 

The Over Temperature Status or OT status is "1" in case of 
an over temperature, the display will show the OT symbol and 
the output shuts down.  

 

The Current Control Status or CC-status output is "1" when 
the unit is in CC-mode. 

 

The Power Sink OverLoad Status or  PSOL-status is not used 
on the SM15K - it is only for SM3300. 

 

The AC-Fail Status or ACF-status output is "1" in case the 
input voltage is too low or too high. 

 

The DC-Fail Status or DCF-status output is "1" when the 
output voltage is either 5% below or above the set point.  

 

The table in the interface datasheet shows the impedance 
levels of the status outputs.  

 

See figure 7 - 7 for a connection diagram. 

7.9

 

REMOTE SHUTDOWN 

 

A voltage of +4 V...+12 V on the Remote ShutDown input on 
the programming connector will switch off the output of the 
unit. 

 

If the input is high, the RSD icon is shown in the display, see 
fig 7 - 8. 

 

It is also possible to use a relay contact or a switch to shut the 
unit down (see fig. 7 - 9).  

 

In standby mode the power supply consumes very little 
power. 

 

Note: also via Eth or other interfaces RSD can be activated. 

7.10

 

REFERENCE VOLTAGE 

 

A 5.114V reference voltage is available on the connector. 
This reference can be used to control the unit with external 
potentiometers. 

7.11

 

AUX12V 

 

The 12V on the programming connector can be used to 
supply external circuits. The output current is fuse protected 
at 0.2A and should not be overloaded. 

 

Output impedance is 5 Ohms. 

7.12

 

TROUBLE SHOOTING 

7.12.1

 

 PROGRAMMING DOES NOT WORK OK 

 

Check the programming source is the correct slot. 

 

Check that there is only 1 analog interface installed. 

 

Check the output is switched ON, the Interlock is connected 
and Remote ShutDown is low. 

7.12.2

 

 STATUS OUTPUT FAIL 

 

Check the wiring of the analog programming connector for 
short circuit or loose contacts.  

 

If the front display shows a status icon, but the logic output on 
the interface remains low, send the unit back for repair. 

7.13

 

CALIBRATION 

 

The isolated analog interface is factory calibrated. 

 

If desired, both the 5 V and 10 V range can be custom 
calibrated. See the ethernet programming manual for more 
details. 

 

fig 7 - 8 

Position of the RSD icon in the unit display. 

 

 

fig 7 - 9 

Remote ShutDown using a relay contact. 

Summary of Contents for SM15K Series

Page 1: ...on P0120 Contents 1 Safety Instructions 2 Sicherheitshinweise 3 Master Slave Interface 4 Isolated Contacts 5 Serial Interface 6 Digital User I O 7 Isolated Analog Interface Firmware Update It is stron...

Page 2: ...nd either the minus or plus DC power terminal is grounded the voltage on the DC power terminals and sense connections can be considered safe Caution 1 If a low voltage unit has both DC power terminals...

Page 3: ...covers Safety cover s are used to cover potentially hazardous voltages Observe the following when removing safety cover s Switch off the unit Disconnect the unit from the mains supply or power outlet...

Page 4: ...als sicher angesehen werden wenn die minus DC Anschlussklemme des Ger ts im Verh ltnis zur Erdung 1000 VDC 707 Vpk nicht berschreitet f r SM70 CP 450 SM210 CP 150 und SM500 CP 90 oder 1500VDC 1060Vpk...

Page 5: ...ie Folgendes wenn Sie die Sicherheitsabdeckung en entfernen Ger t ausschalten Ger t von dem Versorgungsnetz oder der Stromquelle trennen Warten Sie 5 Minuten damit interne Kondensatoren sich entladen...

Page 6: ...er In the front menu go to SYSTEM INFO UNIT VERSION If an update is required refer to the SM15K unit manual how to do this 3 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs...

Page 7: ...first insert the bolts with crinkle washers in all DC power terminals Then assemble the entire strip to the DC power terminals This because bolts cannot be inserted in the DC power terminals once the...

Page 8: ...rip because it will burn out o Place the special M S parallel safety covers over the output terminals o Cover with marking DWG2532 is for the outputs of the upper and lower units Cover DWG2533 is for...

Page 9: ...own in the display see fig 3 6 The master or slave can also be configured via the web interface or using Ethernet commands After changing master or slave settings stored sequences need to be rebuilt d...

Page 10: ...how to do this 4 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs and Outputs or the Sense Connector when the SM15K unit is connected to the mains supply or power outlet Safe...

Page 11: ...N M o 6 Relay 1 NC o 5 Relay 1 NO o 4 Relay 1 Common o 3 Relay 2 NC o 2 Relay 2 NO o 1 Relay 2 Common Pinning CON N o 6 Relay 3 NC o 5 Relay 3 NO o 4 Relay 3 Common o 3 Relay 4 NC o 2 Relay 4 NO o 1 R...

Page 12: ...to the SM15K unit manual how to do this 5 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs and Outputs or the Sense Connector when the SM15K unit is connected to the mains su...

Page 13: ...e monitored Download the manual Ethernet Sequencer Programming SM15K for details 5 9 TROUBLE SHOOTING Check the programming source is set to the correct slot Check the output is switched ON the Interl...

Page 14: ...the unit must be in CC mode and when programming a power the unit must be in CP mode 5 10 CALIBRATION Calibration of the interface is not applicable 5 11 Settings Settings via the web page o Bus type...

Page 15: ...red refer to the SM15K unit manual how to do this 6 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs and Outputs or the Sense Connector when the SM15K unit is connected to th...

Page 16: ...pin 15 The user inputs have a working range of 2V 30V use a common zero and have an impedance of approximately 22kOhms The maximum load of the 5V is 100mA See figure 6 4 and table 6 1 for the pinning...

Page 17: ...mware package is P0120 or higher In the front menu go to SYSTEM INFO UNIT VERSION If an update is required refer to the SM15K unit manual how to do this 7 4 HARDWARE INSTALLATION Warning Never make co...

Page 18: ...afe value Note that the programming inputs are floating with regards the power output Turn the output on again with the OUTPUT ON OFF button To program the unit by current instead of voltage simply us...

Page 19: ...ble to use a relay contact or a switch to shut the unit down see fig 7 9 In standby mode the power supply consumes very little power Note also via Eth or other interfaces RSD can be activated 7 10 REF...

Reviews: