For example it is not possible to program a voltage when the
current and power control is set to zero.
Check that the power supply is in the required mode (CV or
CC or CP). When programming a voltage, the unit must be in
CV-mode, when programming a current, the unit must be in
CC-mode and when programming a power, the unit must be
in CP-mode.
5.10
CALIBRATION
Calibration of the interface is not applicable.
5.11
Settings
Settings via the web page.
o
Bus type : USBcom
o
Device channel nr : ch 1
o
Baudrate : bps 9600
o
Data bits : 8
o
Stop bits : 1
o
Flow control : None
o
Parity bits : None
o
Slewrate : Disabled
o
Termination : Disabled
o
Differential communication : Half-duplex
Port settings on the PC.
o
Baudrate : bps 9600
o
Data bits : 8
o
Parity bits : None
o
Stop bits : 1
o
Flow control : None