DeviceNet Slave Communication Card CMC-DN01
DVP-PLC Operation Manual
19
LED status
Indication
How to correct
5. Check if the power supply for the network is
normal.
7.3 MS
LED
LED status
Indication
How to correct
Off
No power supply or being
offline
Check the power supply of CMC-DN01 and see if
the connection is normal.
Green light
flashes
Waiting for I/O data
Switch the master PLC to RUN status.
Green light
on
I/O data are normal.
--
Red light
flashes
Mapping error
1. Re-configure CMC-DN01.
2. Re-power the AC motor drive.
Red light on Hardware error
1. See the error code displayed on the AC motor
drive.
2. Send back to factory for repair if necessary.
Orange light
flashes
CMC-DN01 is establishing
connection with the AC
motor drive.
If the flashing lasts for a long time, check if
CMC-DN01 and the AC motor drive are correctly
installed and normally connected to each other.