![Delta Electronics ASD-B0121-A User Manual Download Page 213](http://html1.mh-extra.com/html/delta-electronics/asd-b0121-a/asd-b0121-a_user-manual_2476011213.webp)
Chapter 7 Servo Parameters
|
ASDA-B Series
7-60
Revision January, 2009
P4 - 05
JOG
JOG Operation
Communication Addr.: 0405H
Default: 20
Related Section:
Applicable Control Mode: P/S/T
Section 4.4.3
Unit: rpm
Range: 0 ~ 5000
Settings:
JOG operation command:
To perform a JOG Operation via communication command, use communication address 0405H
Enter 0 ~ 4997 for the desired JOG rpm. The setting value will be written into P4-05.
If the setting value exceeds the motor rated speed, this parameter is not be effective and the
motor will stop.
Enter 4998 to JOG in the CCW direction
Enter 4999 to JOG in the CW direction
Enter 5000 to stop the JOG operation
If change the speed during JOG operation, the new setting value is effective only after the servo
drive is restarted (after switching power off and on).
NOTE
1) If the communication write-in frequency is too high, please set P2-30 to 5.
P4 - 06
▲
■
FOT
Force Output Control
Communication Addr.: 0406H
Default: 0
Related Section:
Applicable Control Mode: P/S/T
Section 4.4.4
Unit: N/A
Range: 0 ~ 7
Settings:
0: Disabled
This parameter is used to check if there is any damage DO terminal. This parameter is not
effective when the servo drive is enabled (Servo ON).
When the value of P4-06 is a non-zero value, it indicates this function is enabled.
For example:
When P4-06 is set to 3, it indicates that DI 1 and DI 2 are both ON.
NOTE
1) When users select P4-06 and press the Set key, the display will show “OP x”. “x” stands for
the parameter range from 0 to 7 (For the example display, refer to Section 4.4.4).
Summary of Contents for ASD-B0121-A
Page 1: ......
Page 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Page 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Page 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Page 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Page 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Page 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Page 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Page 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Page 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Page 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Page 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Page 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Page 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...