Chapter 6 Control Modes of Operation
|
ASDA-B Series
6-30
Revision January, 2009
6.5.2 Speed / Torque Control Mode Selection
S-T Mode:
The speed command can be the external analog voltage or internal parameters (P1-09 to P1-11) and
SPD0~1 is used to select speed command. The same as speed command, the torque command can be
the external analog voltage or internal parameters (P1-12 to P1-14) and TCM0~1 is used to select
torque command. The speed and torque mode switching is controlled by the S-T signal.
The timing chart of speed / torque control mode selection is shown as the figure below:
ON
NOT CARE
NOT CARE
OFF
ON
S-T
NOT CARE
Speed source is determined
by SPD0~1
Torque source is determined
by TCM0~1
Speed Mode
Torque Mode
Torque Mode
Torque source is determined
by TCM0~1
In torque mode (when S-T is ON), torque command is selected by TCM0~1. When switching to the
speed mode (when S-T is OFF), the speed command is selected by SPD0~1, and then the motor will
immediately rotate following the command. After S-T is ON again, it will immediately return to torque
mode.
6.5.3 Torque / Position Control Mode Selection
T-P Mode:
The command source of T-P mode is from external input pulse. The torque command can be the
external analog voltage or internal parameters (P1-12 to P1-14). The torque and position mode
switching is controlled by the T-P signal.
The timing chart of speed / position control mode selection is shown as the figure below:
ON
NOT CARE
Torque source is determined
by TCM0~1
Counting Pulse
Position Mode
NOT CARE
OFF
ON
T-P
Torque Mode
Position Mode
Counting Pulse
Stop Counting Pulse
In position mode (when T-P is ON), the motor will start to count pulse and operate following the external
pulse command. When switching to the torque mode (when T-P is OFF), it will stop counting pulse even
if the pulse command is continuously sent out. The torque command is determined by TCM0~1 and the
motor will rotate following the command. After T-P is ON again, it will immediately return to position
mode.
Summary of Contents for ASD-B0121-A
Page 1: ......
Page 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Page 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Page 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Page 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Page 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Page 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Page 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Page 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Page 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Page 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Page 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Page 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Page 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...