6-05
Over-Torque Detection Time
d0.1 to d10.0 Sec
d0.1
6-06
Electronic Thermal Overload Relay
Selection
d0 to d2
d2
6-07
Electronic Thermal
Characteristic
d30 to d600 Sec
d60
d0: No fault
d1: Over current (oc)
d2: Over voltage (ov)
d3: Over heat (oH)
6-08
Present Fault Record
d4: Over load (oL)
d5: Over load (oL1)
d6: External fault (EF)
6-09
Second Most Recent Fault Record
d7: Reserved
d8: Reserved
d9: Excess current during
acceleration (ocA)
d10: Excess current during
deceleration (ocd)
d11: Excess current during steady
state (ocn)
6-10 Third Most Recent Fault Record
d12: Ground fault (GF)
d0
d13:
Reserved
d14: Low voltage (Lv)
d15: CPU failure 1 (cF1)
d16: CPU failure 2 (cF2)
d17: Base block (b.b.)
d18: Overload (oL2)
d19: Auto acceleration/deceleration
failure (cFA)
d20: Software protection enable
(codE)
d21:
Reserved
d22: CPU failure (cF3.1)
d23: CPU failure (cF3.2)
d24: CPU failure (cF3.3)
d25: CPU failure (cF3.4)
d26: CPU failure (cF3.5)
d27: CPU failure (cF3.6)
d28: CPU failure (cF3.7)
d29: Hardware protection failure
(HPF.1)
d30: Hardware protection failure
(HPF.2)
d31: Hardware protection failure
(HPF.3)
d32: Communication time-out
(CE10)
d33:
Reserved
d34: Software error (SErr)
d35: Reserved
d36: PID error (Pld)
d37: Reserved
d38: Phase loss (PHL)
d0