Chapter 2 Installation and Wiring
|
VFD-S Series
2-24
Revision August 2006, SE08, SW V2.61
2.4.4 Control Terminals
Control Terminal Wiring (Factory Setting)
A. XXXSXXA/B/D/U
RA
M1
AVI
10V
+
AFM
M0
M4
M2 M3
M5
GND
RB
RC
MO1
MCM
RJ11
Multi-step speed 3
Multi-step speed 2
Multi-step speed 1
Reset
Reverse/Stop
Forward/Stop
Corrector
potentiometer
VR : 1K~5K
Freq. meter
0~10 VDC
Full scale voltmeter
Operation freq.
setting
potentiometer
VR : 3K~5K
Relay contactor output
Factory setting : Fault indication
Photo coupler output
Factory setting : in work
6 ~ 1
RS485 Communication port
B. XXXSXXE
Multi-step speed 3
*
*
Terminal symbols and functions
Terminal
Symbol
Terminal Function
Factory Settings (NPN mode)
ON: Connect to GND
M0
Multi-function auxiliary input
M1
Multi-function input 1
M2
Multi-function input 2
M3
Multi-function input 3
Refer to Pr.4-04 to Pr.4-08 for programming the
Multi-function Inputs.
ON: the activation current is 16mA.
OFF: leakage current tolerance is 10
μ
A.
Wire Gauge: 24-12 AWG
Wire Type: Copper Only
Torque: 4 kgf-cm (3.5 in-lbf)
Wire Gauge: 24-16 AWG
Wire Type: Copper Only
Torque: 2 kgf-cm (1.7 in-lbf)