Chapter 2 Installation and Wiring
|
VFD-S Series
Revision August 2006, SE08, SW V2.61
2-25
Terminal
Symbol
Terminal Function
Factory Settings (NPN mode)
ON: Connect to GND
M4
Multi-function input 4
M5
Multi-function Input 5
+17V
DC Voltage Source
+17VDC, 20mA used for PNP mode.
GND
Digital Signal Common
Common for digital inputs and used for NPN
mode.
AFM
Analog output meter
Internal Circuit
AFM circuit
AFM
GND
0~10V
Max. 2mA
ondometer
RA
Multi-function Relay output
(N.O.) a
RB
Multi-function Relay output
(N.C.) b
RC
Multi-function Relay common
Resistive Load:
5A(N.O.)/3A(N.C.) 240VAC
5A(N.O.)/3A(N.C.) 24VDC
Inductive Load:
1.5A(N.O.)/0.5A(N.C.) 240VAC
1.5A(N.O.)/0.5A(N.C.) 24VDC
Refer to Pr.3-06 for programming
MO1
Multi-function Output 1
(Photocoupler)
Maximum 48VDC, 50mA
Refer to Pr.3-01 for programming
MO1-DCM
Mo1
MCM
M ax: 48Vdc
50mA
internal circuit
MCM Multi-function output common Max. 48Vdc 50mA
+10V
Potentiometer power supply
+10VDC 10mA (variable resistor: 3~5kohm)