64
AWR-MTD2-XE
EN 11/2010
LIST OF PARAMETERS
U I A
Description
Menu Parameter no. UOM
Enable domestic hot water set point: 0 = Economy, 1 = Comfort
Mn00
0015
Domestic hot water Economy set point
Mn00
0022
°C
Domestic hot water Comfort set point
Mn00
0023
°C
User password
Mn00
0036
Enable remote contact: 0= remote contact enabled, 1= remote contact disabled (selection from keypad only)
Mn01
0100
Automatic mode changeover set point in HEATING
Mn01
0106
°C
Automatic mode changeover differential in HEATING
Mn01
0107
°C
Automatic mode changeover set point in COOLING
Mn01
0108
°C
Automatic mode changeover differential in COOLING
Mn01
0109
°C
Type of outlet heater operation: 0 = Supplementary , 1 = Replacement
Mn01
010G
Type of boiler operation: 0 = Supplementary , 1 = Replacement
Mn01
010H
Maximum return set point limit in cooling mode (Tm1)
Mn01
0128
°C
Outside minimum temperature corresponding to max. return temperature (Te1)
Mn01
0129
°C
Enable compensation for room humidity, ZONE LT3: 0= Disabled , 1= Enabled
Mn01
012N
Room relative humidity value to start increasing water outlet temperature set point, ZONE LT3
Mn01
012P
%
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
Mn01
012R
°C
Minimum return set point limit in cooling mode (Tm2)
Mn01
0130
°C
Maximum outside temperature corresponding to min. return temperature (Te2)
Mn01
0131
°C
Maximum outlet temperature set point limit in cooling mode (Tm1)
Mn01
0132
°C
Minimum outside temperature corresponding to max. outlet temperature (Te1)
Mn01
0133
°C
Minimum outlet temperature set point limit in cooling mode (Tm2)
Mn01
0134
°C
Maximum outside temperature corresponding to min. outlet temperature (Te2)
Mn01
0135
°C
Maximum outlet temperature set point limit in cooling mode (Tm1)
Mn01
0136
°C
Minimum outside temperature corresponding to max. outlet temperature (Te1)
Mn01
0137
°C
Minimum outlet temperature set point limit in cooling mode (Tm2)
Mn01
0138
°C
Maximum outside temperature corresponding to min. outlet temperature (Te2)
Mn01
0139
°C
Inside temperature to enable frost protection
Mn01
0140
°C
Outside air temperature for frost protection
Mn01
0141
°C
Enable SYSTEM compensation curve 0= Disabled 1= Enabled
Mn01
0152
Fixed return water temperature set point in HEATING
Mn01
0153
°C
Enable SYSTEM compensation curve: 0= Disabled, 1= Enabled
Mn01
0154
Fixed return water temperature set point in COOLING
Mn01
0155
°C
Enable compensation for room humidity, SYSTEM: 0= Disabled , 1= Enabled
Mn01
0156
Room relative humidity value to start increasing SYSTEM return water set point
Mn01
0157
%
Maximum return temperature hysteresis corresponding to 100% relative humidity
Mn01
0158
°C
SYSTEM compensation curve number
Mn01
0159
Enable contact as: 0= Alarm signal, 1= Dehumidifier, 3= Secondary circuit pump
Mn01
015A
Enable compensation curve for zone LT3 0= Disabled 1= Enabled
Mn01
015E
Enable room temperature influence on SYSTEM 0= Disabled 1= Enabled
Mn01
0163
SYSTEM Room Authority
Mn01
0164
%
Minimum set point limit for SYSTEM curve
Mn01
0165
°C
Maximum set point limit for SYSTEM curve
Mn01
0166
°C
Enable compensation curve for zone LT1 0= Disabled 1= Enabled
Mn01
0167
Enable compensation curve for zone LT1: 0= Disabled, 1= Enabled
Mn01
0169
Enable compensation for room humidity, ZONE LT1: 0= Disabled , 1= Enabled
Mn01
0171
Room relative humidity value to start increasing water outlet temperature set point, ZONE LT1
Mn01
0172
%
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
Mn01
0173
°C
Zone LT1 compensation curve number
Mn01
0174
Enable room temperature influence on LT1 0= Disabled 1= Enabled
Mn01
0178
LT1 Room Authority
Mn01
0179
%
MINIMUM outlet set point limit for compensation curve in zone LT1
Mn01
0180
°C
MAXIMUM outlet set point limit for compensation curve in zone LT1
Mn01
0181
°C
Enable compensation curve for zone LT2 0= Disabled 1= Enabled
Mn01
0182
Enable compensation curve for zone LT2: 0= Disabled, 1= Enabled
Mn01
0184
Enable compensation for room humidity, ZONE LT2: 0= Disabled , 1= Enabled
Mn01
0186
Room relative humidity value to start increasing water outlet temperature set point, ZONE LT2
Mn01
0187
%
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
Mn01
0188
°C
Zone LT2 compensation curve number
Mn01
0189
Enable room temperature influence on LT2 0= Disabled 1= Enabled
Mn01
0193
LT2 Room Authority
Mn01
0194
%
MINIMUM outlet set point limit for compensation curve in zone LT2
Mn01
0195
°C
MAXIMUM outlet set point limit for compensation curve in zone LT2
Mn01
0196
°C
Electric heater operating mode: 0 = heat pump only, 1 = electric heater only, 2 = heat pump + electric heater
Mn02
0202
Domestic hot water set point with heater
Mn02
0209
°C