32
About Your System
Plug & Play
Configuration
Error.
Error encountered in
initializing PCIe device;
faulty system board.
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists,
see "Troubleshooting
Expansion Cards" on
page 143.
Quad rank DIMM
detected after
single rank or
dual rank DIMM in
socket.
Invalid memory
configuration.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module
Installation Guidelines" on
page 83.
Read fault.
Requested sector
not found.
The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.
Replace the optical medium,
USB medium, or USB
device. Ensure that the USB
cables, SAS/SATA backplane
cables, or optical drive cables
are properly connected.
See "Troubleshooting a USB
Device" on page 130 or
"Troubleshooting a Hard
Drive" on page 140, for the
appropriate drive(s) installed
in your system.
SATA Port
x
device not
found.
There is no device connected
to the specified SATA port.
Information only.
Message
Causes
Corrective Actions
book.book Page 32 Wednesday, March 3, 2010 10:37 AM