Table 28. Event descriptions and recommended actions (continued)
Number
Severity
Description/Recommended actions
This event indicates that the available space in the system is insufficient to provide the level of
full fault tolerance that is specified by the target spare capacity. Spare capacity availability can
be influenced by operations that require available space in the system, such as reconstructing
data from a failed disk.
Recommended actions:
●
Add disks to the disk group, or replace any disks that may have failed. The system will
automatically increase the spare capacity to meet the requirements placed on the system by
the target spare capacity.
618
Resolved
The spare capacity goal is met.
Recommended actions:
●
No action is required.
619
Info.
The controller has been injected with a fault to introduce a broadcast receiver (BR) link error.
Recommended actions:
●
No action is required.
620
Error
Expander zoning is enabled, which may limit disk access.
Disk access will change depending on the port used to connect to the expander.
Recommended actions:
●
Load a valid firmware bundle to disable zoning.
Resolved
Expander zoning has been disabled for the indicated enclosure.
Recommended actions:
●
No action is required.
621
Info.
Degraded ADAPT rebalance operation started. This operation takes fault tolerant stripe zones
and makes them degraded so critical stripe zones can be made degraded.
Recommended actions:
●
No action is required.
622
Info.
Degraded ADAPT rebalance operation completed. This operation takes fault tolerant stripe zones
and makes them degraded so critical stripe zones can be made degraded.
Recommended actions:
●
No action is required.
623
Info.
Management Controller configuration parameters were set.
One or more configuration parameters associated with the Management Controller (MC) have
been changed, such as configuration for SNMP, SMI-S (not supported on the ME5084), email
notification, and system strings (system name, system location, etc.).
Recommended actions:
●
No action is required.
626
Info.
Detected an unsupported TPID (midplane Type ID).
Recommended actions:
●
No action is required.
628
Error
A firmware mismatch has been identified for the expansion enclosure.
A firmware mismatch could result from attaching an enclosure configured as a JBOD (instead of
an EBOD) or installing a new IOM FRU with incompatible firmware.
Recommended actions:
●
Update the firmware to the appropriate level for connecting your expansion enclosures to
the controller enclosure.
130
Events and event messages