Table 28. Event descriptions and recommended actions (continued)
Number
Severity
Description/Recommended actions
●
Check for any obstructions to the airflow.
●
Check that there is a module or blank plate in every module slot in the enclosure.
If the problem persists, replace the controller module that logged the error.
309
Info.
Normally when the Management Controller (MC) is started, the IP settings are obtained from
the midplane FRU ID SEEPROM where it persists. If the system is unable to write it to the
SEEPROM the last time it changed, a flag is set in flash memory. This flag is checked during
startup, and if set, this event is logged and the IP data that is in the SEEPROM is used by the
controller module.
The IP settings of the Management Controller (MC) may be incorrect after a controller module
is swapped or the storage enclosure chassis is replaced.
●
If a controller module is swapped, the IP settings in the flash memory of the replacement
controller module may be used.
●
If the storage enclosure chassis is replaced, the IP settings are lost and they must be
reentered on both controller modules.
Recommended actions:
●
No action is required.
310
Info.
After a rescan, back-end discovery and initialization of data for at least one EMP (Enclosure
Management Processor) has completed. This event is not logged again when processing
completes for other EMPs in the system.
Recommended actions:
●
No action is required.
311
Info.
This event is logged when a user initiates a ping of a host using the iSCSI interface.
Recommended actions:
●
If the ping operation failed, check connectivity between the storage system and the remote
host.
313
Error
The indicated controller module has failed. This event can be ignored for a single-controller
configuration.
Recommended actions:
●
If this is a dual-controller system, replace the failed controller module. The module’s Fault/
Service Required LED will be illuminated (not blinking).
314
Error
The indicated FRU has failed or is not operating correctly. This event follows some other FRU-
specific event indicating a problem.
Recommended actions:
●
To determine whether the FRU needs to be replaced, see the topic about verifying
component failure in your product's Hardware Installation and Maintenance Guide.
315
Critical
This IOM is incompatible with the enclosure in which it is inserted.
Recommended actions:
●
Replace this IOM with an IOM that is compatible with this enclosure.
317
Error
A serious error has been detected on the Storage Controller disk interface. The controller will be
killed by its partner.
Recommended actions:
●
Visually trace the cabling between the controller modules and expansion modules.
●
If the cabling is OK, replace the controller module that logged this event.
●
If the problem recurs, replace the expansion module that is connected to the controller
module.
319
Warning
The indicated available disk has failed.
100
Events and event messages