![Dell PowerVault ME5 Series Owner'S Manual Download Page 106](http://html.mh-extra.com/html/dell/powervault-me5-series/powervault-me5-series_owners-manual_85929106.webp)
Table 28. Event descriptions and recommended actions (continued)
Number
Severity
Description/Recommended actions
467
Info.
Addition of the indicated disk group completed successfully.
Recommended actions:
●
No action is required.
468
Info.
FPGA temperature has returned to the normal operating range and the speed of buses
connecting the FPGA to downstream adapters has been restored. The speed was reduced to
compensate for an FPGA over-temperature condition.
This event indicates that a problem reported by event 469 is resolved.
Recommended actions:
●
No action is required.
469
Warning
The speed of buses connecting the FPGA to downstream adapters has been reduced to
compensate for an FPGA over-temperature condition.
The storage system is operational but I/O performance is reduced.
Recommended actions:
●
Check that the storage system’s fans are running.
●
Check that the ambient temperature is not too warm. The controller enclosure operating
range is 5°C to 35°C (41°F to 95°F). The expansion enclosure operating range is 5°C to
40°C (41°F to 104°F).
●
Check for any obstructions to the airflow.
●
Check that there is a module or blank plate in every module slot in the enclosure.
●
If none of these recommended actions resolve the issue, replace the controller module that
logged the error.
When the problem is resolved, event 468 is logged.
470
Warning
Removal of the indicated disk groups completed with failure.
Removal of disk groups can fail for several reasons, and the specific reason for this failure
is included with the event. Removal most often fails because there is no longer room in the
remaining pool space to move data pages off of the disks in the disk group.
Recommended actions:
●
Resolve the issue specified by the error messaging included with this event and re-issue the
request to remove the disk group.
Info.
Removal of the indicated disk groups completed successfully.
Recommended actions:
●
No action is required.
473
Info.
The indicated volume is using more than its threshold percentage of its virtual pool.
This is an indication that the storage usage crossed the threshold for this volume. If the storage
usage drops below the threshold, event 474 is logged.
Recommended actions:
●
No action is required. How this information is utilized is left to the discretion of the user.
474
Info.
The indicated volume is no longer using more than its threshold percentage of its virtual pool.
This event indicates that the condition reported by event 473 is no longer applicable.
Recommended actions:
●
No action is required.
476
Warning
The CPU temperature exceeded the safe range so the CPU entered its self-protection state.
IOPS were reduced.
The storage system is operational but I/O performance is reduced.
Recommended actions:
106