![Dell PowerVault ME5 Series Owner'S Manual Download Page 128](http://html.mh-extra.com/html/dell/powervault-me5-series/powervault-me5-series_owners-manual_85929128.webp)
Table 28. Event descriptions and recommended actions (continued)
Number
Severity
Description/Recommended actions
●
No action is required.
608
Error
A back-end cabling error was detected.
Recommended actions:
●
If the message says both controllers are connected with a undefined error type, one
of the cables is incorrectly connected to a controller egress port forming a loop in the
SAS topology. Check back-end cabling from each controller egress port to determine the
incorrect connection.
●
If the message says controller egress ports are connected to each other, one of the cables is
incorrectly connected to a controller egress port forming a loop in the SAS topology. Check
back-end cabling and make sure that SAS cables are connected to the correct ports for the
port specified.
●
If the message says an EBOD loop has been created, one of the cables is incorrectly
connected to an expansion enclosure egress port forming a loop in the SAS topology. Check
back-end cabling and make sure that SAS cables are connected to the correct ports for the
port specified.
●
If the message says a cable is connected to the middle port but that port is not supported,
check back-end cabling and make sure that SAS cables are connected to the correct ports
for the port specified. Move the cable from the middle port of the IOM to the left or right
port, as appropriate.
609
Error
An alert condition was detected on a door lock element. The door lock element reports status
associated with the enclosure drawer. The drawer has been reporting as open for a long period
of time. This may reduce cooling, potentially causing the enclosure to overheat.
Recommended actions:
●
Check that the drawer is fully closed and latched.
When the problem is resolved, an event with the same code will be logged with Resolved
severity.
Info.
An alert condition was detected on a door lock element. The door lock element reports status
associated with the enclosure drawer. The drawer sensor is reporting uninstalled.
Recommended actions:
●
No action is required.
Resolved
A previous Informational or Error condition for the door lock element has been resolved.
Recommended actions:
●
No action is required.
610
Error
An alert condition was detected on a sideplane element.
Recommended actions:
●
Check the drawer that the indicated sideplane is fully closed and latched.
CAUTION:
The sideplanes on the enclosure drawers are not hot swappable or
customer serviceable.
●
If this does not resolve the issue, contact technical support. The enclosure must be replaced.
Warning
An alert condition was detected on a sideplane element.
Recommended actions:
●
The sideplane associated with the drawer must be installed. Contact technical support.
CAUTION:
The sideplanes on the enclosure drawers are not hot swappable or
customer serviceable.
Resolved
A previous Warning or Error condition for the sideplane element has been resolved.
Recommended actions:
●
No action is required.
611
Error
Email notification failed due to either:
128
Events and event messages