Script Commands
159
Parameters
None.
NOTE:
This command resets the baseline to 0 for both RAID controller modules in
the storage array. The purpose of resetting both of the RAID controller module
baselines is to help ensure that the counts are synchronized between the RAID
controller modules. If one RAID controller module resets but the second RAID
controller module does not reset, the host is informed that the RAID controller
modules are out of synchronization. The host is informed by the time stamps that
are reported with the statistics.
Example
-c "reset storageArray iscsiStatsBaseline;"
Reset Storage Array SAS PHY Baseline
This command resets the SAS PHY baseline for all SAS devices in a storage
array.
Syntax
reset storageArray SASPHYBaseline
Parameters
None.
Example
-c "delete host [\"job2900\"];"
Reset Storage Array Virtual Disk Distribution
This command reassigns (moves) all virtual disks to their preferred RAID
controller module.
Syntax
reset storageArray virtualDiskDistribution
Parameters
None.
Summary of Contents for PowerVault MD3000i
Page 12: ...12 Contents ...
Page 42: ...42 About the Script Commands ...
Page 90: ...90 Using the Virtual Disk Copy Feature ...
Page 104: ...104 Maintaining a Storage Array ...
Page 222: ...222 Script Commands ...
Page 228: ...228 Sample Script Files ...
Page 236: ...236 Index ...