Script Commands
179
Parameters
Set Session
This command defines how you want the current script engine session to run.
Syntax
set session errorAction=(stop | continue)
password="
storageArrayPassword"
performanceMonitorInterval=
intervalValue
performanceMonitorIterations=
iterationValue
Parameters
Parameter
Description
physicalDisk
Identifies the enclosure and slot where the physical disk
resides. Enclosure ID values are 0 to 99. Slot ID values
are 0 to 31. You must put brackets ([ ]) around the
enclosure ID value and the slot ID value.
Parameter
Description
errorAction
Specifies how the session responds if an error is
encountered during processing. You can choose to
stop the session if an error is encountered, or you can
continue after encountering an error. The default
error action is to stop. (This parameter defines the
action for execution errors, not syntax errors. Some
error conditions might override the
continue
value.)
password
Specifies the password for the storage array. You
must put quotation marks (" ") around the password.
NOTE:
Passwords are stored on each storage array in
a management domain. If a password was not
previously set, you do not need a password. The
password can be any combination of alphanumeric
characters with a maximum of 30 characters. (You can
define a storage array password by using the
set
storageArray
command.)
Summary of Contents for PowerVault MD3000i
Page 12: ...12 Contents ...
Page 42: ...42 About the Script Commands ...
Page 90: ...90 Using the Virtual Disk Copy Feature ...
Page 104: ...104 Maintaining a Storage Array ...
Page 222: ...222 Script Commands ...
Page 228: ...228 Sample Script Files ...
Page 236: ...236 Index ...