Ensure that you follow the
Safety instructions
.
Steps
1.
Align the slots on the power interposer board (PIB) with the hooks on the power supply unit (PSU)
cage and slide the PIB until it snaps into place.
2.
Route the power cables through the securing clips as applicable, and connect the power cables to
the system board.
Next steps
1.
Install the cooling shroud.
2.
Install the PSUs or PSU blank.
3.
Follow the procedure listed in
After working inside your system
.
Related Tasks
Installing the cooling shroud
Installing a redundant AC power supply unit
Installing the power supply unit blank
System battery
Replacing the system battery
Prerequisites
1.
Ensure that you follow the
Safety instructions
.
2.
Follow the procedure listed in
Before working inside your system
.
3.
Remove the cooling shroud.
4.
Keep the plastic scribe ready.
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the
battery only with the same or equivalent type recommended by the manufacturer. For more
information, see the safety information that shipped with your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures must be
performed only by Dell certified service technicians.
Steps
1.
Locate the battery socket. For more information, see
System board jumpers and connectors
.
CAUTION: To avoid damage to the battery connector, you must firmly support the connector
while installing or removing a battery.
2.
Use a plastic scribe to pry out the system battery as shown in the following illustration:
118