34
About Your System
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 195.
E2010
Memory not
detected.
Inspect
DIMMs.
No memory detected in the
system.
Install memory or reseat
the memory modules. See
"Installing Memory
Modules" on page 105 or
"Troubleshooting System
Memory" on page 169.
E2011
Memory
configuratio
n failure.
Check DIMMs.
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 169.
E2012
Memory
configured
but unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory" on
page 169.
E2013
BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 169.
E2014
CMOS RAM
failure.
Power cycle
AC.
CMOS failure. CMOS RAM
not functioning properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E2015
DMA
Controller
failure.
Power cycle
AC.
DMA controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
Code
Text
Causes
Corrective Actions
book.book Page 34 Thursday, February 18, 2010 2:06 PM
Summary of Contents for PowerEdge R810
Page 1: ...Dell PowerEdge R810 Hardware Owner s Manual Regulatory Model E05S Regulatory Type E05S001 ...
Page 80: ...80 Using the System Setup Program and UEFI Boot Manager ...
Page 160: ...160 Installing System Components ...
Page 194: ...194 Jumpers and Connectors ...
Page 196: ...196 Getting Help ...
Page 202: ...Index 202 ...