E201C
SMI Init
System management
interrupt (SMI)
initialization failure.
See "Getting Help" on
page 175.
E201D
Shutdown Test
BIOS shutdown test failure. See "Getting Help" on
page 175.
E201E
POST Mem Test
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 150. If problem
persists, see "Getting
Help" on page 175.
E201F
DRAC Config
Dell remote access
controller (DRAC)
configuration failure.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If
problem persists, see your
DRAC documentation.
E2020
CPU Config
CPU configuration failure.
Check screen for specific
error messages.
E2021
Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 150.
E2022
POST Fail
General failure after video.
Check screen for specific
error messages.
E2110
MBE DIMM # &
#
One of the DIMMs in the
set implicated by "# & #"
has had a memory multi-bit
error (MBE).
See "Troubleshooting
System Memory" on
page 150.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Summary of Contents for PowerEdge R805 System
Page 46: ...46 About Your System ...