About Your System
23
Table 1-6.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user in
the System Setup program.
The
SYSTEM NAME
displays under the following
conditions:
• The system is powered on.
• The power is off and
active errors are displayed.
This message is for
information only.
You can change the
system ID and name in
the System Setup
program. See "Using the
System Setup Program"
on page 47.
E1000
FAILSAFE,
Call Support
Check the system event log
for critical failure events.
See "Getting Help" on
page 175.
E1114
Temp Ambient
Ambient system
temperature is out of
acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 149.
E1118
CPU Temp
Interface
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan speed
to maximum
as a precautionary measure.
Turn off power to the
system and restart the
system. If the problem
persists, see "Getting
Help" on page 175.
E1210
CMOS Batt
CMOS battery is missing, or
the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 147.
E1211
ROMB Batt
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "RAID
Battery" on page 87, and
"Troubleshooting System
Cooling Problems" on
page 149.
E1214
E1216
E1217
##
PwrGd
Specified voltage regulator
has failed.
See "Getting Help" on
page 175.
Summary of Contents for PowerEdge R805 System
Page 46: ...46 About Your System ...
Page 176: ...176 Getting Help ...
Page 192: ...192 Glossary ...
Page 200: ...200 Index ...