![Dell PowerEdge R805 System Hardware Owner'S Manual Download Page 25](http://html.mh-extra.com/html/dell/poweredge-r805-system/poweredge-r805-system_hardware-owners-manual_85484025.webp)
About Your System
25
E1232
VDD 12V PS#
PwrGd
The specified power supply
has failed or has been
removed from the bay while
the system was on.
If removed, reinsert the
power supply into the bay
and reconnect to power.
For component failures,
see "Getting Help" on
page 175.
E123B
LOM Mezz
PwrGd
Voltage regulator for the
LOM daughter card has
failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 175.
E123C
Planar LOM
PwrGd
Voltage regulator for the
integrated LOM has failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 175.
E1310
RPM Fan ##
RPM of specified cooling
fan is out of acceptable
operating range.
See "Troubleshooting
System Cooling
Problems" on page 149.
E1313
Fan
Redundancy
The system is no longer fan-
redundant. Another fan
failure will put the system at
risk of over-heating.
Check control panel LCD
for additional scrolling
messages. See
"Troubleshooting System
Cooling Problems" on
page 149.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Summary of Contents for PowerEdge R805 System
Page 46: ...46 About Your System ...
Page 176: ...176 Getting Help ...
Page 192: ...192 Glossary ...
Page 200: ...200 Index ...