![Dell PowerEdge R805 System Hardware Owner'S Manual Download Page 26](http://html.mh-extra.com/html/dell/poweredge-r805-system/poweredge-r805-system_hardware-owners-manual_85484026.webp)
26
About Your System
E1414
CPU #
Thermtrip
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling
Problems" on page 149. If
the problem persists,
ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 160.
NOTE:
The LCD continues
to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL is
cleared using either Server
Assistant or the BMC
Management Utility. See
the
Dell OpenManage™
Baseboard Management
Controller User’s Guide
for
information about these
utilities.
E1418
CPU #
Presence
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
See "Troubleshooting the
Microprocessors" on
page 160.
E141C
CPU Mismatch
Processors are in a
configuration unsupported
by Dell.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s
Getting
Started Guide
.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Summary of Contents for PowerEdge R805 System
Page 46: ...46 About Your System ...
Page 176: ...176 Getting Help ...
Page 192: ...192 Glossary ...
Page 200: ...200 Index ...