Error Code
Message Information
MEM0007
Message
Unsupported memory configuration; check memory device
at location <
location
>.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting Help
.
MEM0701
Message
Correctable memory error rate exceeded for <
location
>.
Details
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
MEM0702
Message
Correctable memory error rate exceeded for <
location
>.
Details
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
MEM1205
Message
Memory mirror redundancy is lost. Check memory device at
location(s) <
location
>.
Details
The memory may not be seated correctly, misconfigured, or
has failed.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting Help
.
MEM1208
Message
Memory spare redundancy is lost. Check memory device at
location <
location
>.
Details
Memory sparing is no longer available.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
MEM8000
Message
Correctable memory error logging disabled for a memory
device at location <
location
>.
Details
Errors are being corrected but no longer logged.
Action
Review system logs for memory exceptions. Reinstall
memory at location <