Menu Item
Description
Embedded NIC1
and NIC2
Allows you to enable or disable the embedded network interface cards 1 and 2. By
default, the
Integrated Network Card 1
option is set to
Enabled
.
OS Watchdog
Timer
Allows you to enable or disable the OS watchdog timer. When this field is enabled,
the operating system initializes the timer and the OS watchdog timer helps in
recovering the operating system. By default, the
OS Watchdog Timer
option is set
to
Disabled
.
Embedded Video
Controller
Allows you to enable or disable the
Embedded Video Controller
. By default, the
embedded video controller is
Enabled
.
Memory Mapped
I/O above 4GB
Allows you to enable support for PCIe devices that require large amounts of
memory. By default, the option is set to
Enabled
.
Slot Disablement
Allows you to enable or disable available PCIe slots on your system. The
Slot
Disablement
feature controls the configuration of PCIe cards installed in the
specified slot.
CAUTION: Slot disablement must be used only when the installed peripheral
card is preventing booting into the Operating System or causing delays in
system startup. If the slot is disabled, both the Option ROM and UEFI driver
are disabled.
Serial Communications Screen
Menu Item
Description
Serial
Communication
Allows you to select serial communication devices (Serial Device 1 and Serial
Device 2) in the BIOS. BIOS console redirection can also be enabled and the port
address used can be specified. By default,
Serial Communication
option is set to
On without Console Redirection
.
Serial Port Address Allows you to set the port address for serial devices. By default, the
Serial Port
Address
option is set to
Serial Device 1=COM2, Serial Device 2=COM1
.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use
console redirection by SOL, configure the same port address for console
redirection and the serial device.
External Serial
Connector
Allows you to associate the external serial connector to serial device 1, serial device
2, or remote access device. By default, the
External Serial Connector
option is set
to
Serial Device1
.
NOTE: Only Serial Device 2 can be used for SOL. To use console redirection
by SOL, configure the same port address for console redirection and the serial
device.
Failsafe Baud Rate
Displays the failsafe baud rate for console redirection. The BIOS attempts to
determine the baud rate automatically. This failsafe baud rate is used only if the
attempt fails and the value must not be changed. By default, the
Failsafe Baud Rate
option is set to
115200
.
18
Summary of Contents for PowerEdge R220
Page 1: ...Dell PowerEdge R220 Owner s Manual Regulatory Model E10S Regulatory Type E10S003 ...
Page 81: ...81 ...