26
About Your System
E1A18
PDB Ctrl
Cable
Control cable for the power
distribution board (PDB) is
missing or bad
Reseat the cable. If the
problem persists, replace
the cable.
E2010
No Memory
No memory is installed in
the system.
Install memory. See
"System Memory" on
page 111.
E2011
Mem Config
Err
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 146.
E2012
Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 146.
E2013
Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 146.
E2014
CMOS Fail
CMOS failure. CMOS RAM
not functioning properly.
See "Getting Help" on
page 175.
E2015
DMA
Controller
DMA controller failure.
See "Getting Help" on
page 175.
E2016
Int
Controller
Interrupt controller failure.
See "Getting Help" on
page 175.
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on
page 175.
E2018
Prog Timer
Programmable interval
timer error.
See "Getting Help" on
page 175.
E2019
Parity Error
Parity error.
See "Getting Help" on
page 175.
E201A
SIO Err
SIO failure.
See "Getting Help" on
page 175.
E201B
Kybd
Controller
Keyboard controller failure.
See "Getting Help" on
page 175.
Table 1-5.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions