34
About Your System
Memory address line
failure at
address
,
read
value
expecting
value
Memory double word
logic failure at
address
, read
value
expecting
value
Memory odd/even
logic failure at
address,
read
value
expecting
value
Memory write/read
failure at
address
,
read
value
expecting
value
Faulty or improperly
installed memory
modules.
See "Troubleshooting System
Memory" on page 146.
Memory tests
terminated by
keystroke
POST memory test
terminated by pressing
the spacebar.
Information only.
No boot device
available
Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no bootable
USB key installed.
Use a bootable USB key, CD,
or hard drive. If the problem
persists, see
"Troubleshooting an Internal
USB Memory Key" on
page 148 and
"Troubleshooting a Hard
Drive" on page 153. See
"Using the System Setup
Program" on page 41 for
information on setting the
order of boot devices.
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 34 Sunday, June 21, 2009 10:04 AM
Summary of Contents for PowerEdge HR675
Page 10: ...10 Contents ...
Page 174: ...174 Jumpers and Connectors ...
Page 176: ...176 Getting Help ...
Page 188: ...188 Glossary ...