PowerConnect B-MLXe Hardware Installation Guide
141
53-1002111-01
Displaying image versions
6
Code Flash
The model number and size of the management module flash memory.
IronWare Image (Primary or
Secondary)
Indicates the IronWare image installed in the primary or secondary
location in the management module flash memory. The image must be
xmr<xxxxx>. The actual image name depends on the version of software
you have running on your router.
The output displays the following information about the image:
•
Version – “5.1.0
Txxy
” indicates the image version number. “
xx
”
indicates the hardware type; “
y
” indicates the image type.
•
Size – The size, in bytes, of the image.
•
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
•
Compilation date and time – The date and time that the image was
compiled.
Line Processor (LP) Kernel Image
(Monitor for LP Image Type 0)
Indicates the interface module monitor image stored in the
management module flash memory. The image must be xmlb <xxxxx>.
The management module stores these images only; it does not run the
images. The output displays the following information about the image:
•
Version – “5.1.0T
xxy
” indicates the image version number. “
xx
”
indicates the hardware type; “
y
” indicates the image type.
•
Size – The size, in bytes, of the image.
•
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
•
Compilation date and time – The date and time that the image was
compiled.
LP IronWare Image (Primary or
Secondary for LP Image Type 0)
Indicates the interface module primary and secondary IronWare image
stored in the management module flash memory if you copied the
primary and secondary IronWare image to all interface modules using
the copy command with the all keyword. The management module
stores these images only; it does not run the images. The image must be
xmlp <xxxxx>. The output displays the following information about the
image:
•
Version – “5.1.0
Txxy
” indicates the image version number. “
xx
”
indicates the hardware type; “
y
” indicates the image type.
•
Size – The size, in bytes, of the image.
•
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
•
Compilation date and time – The date and time that the image was
compiled.
Monitor Image
Indicates the monitor image installed in the management module flash
memory. The image must be xmb <xxxxx>. The output displays the
following information about the image:
•
Version – “5.1.0
Txxy
” indicates the image version number. “
xx
”
indicates the hardware type; “
y
” indicates the image type.
•
Size – The size, in bytes, of the image.
•
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
•
Compilation date and time – The date and time that the image was
compiled.
TABLE 28
Description of the show flash command output (Continued)
Field
Definition
Summary of Contents for PowerConnect B - MLXe 16
Page 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Page 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Page 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Page 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...