PowerConnect B-MLXe Hardware Installation Guide
65
53-1002111-01
Installing a PowerConnect B-MLXe-16 router
2
b. With the module designation from show running-config command output, use the no
module <
slot-number
> <
module-type
> command to remove the configuration from slot 1.
MLXe-16(config)# no module 1 ni-mlx-24-port-1g-copper
This command removes the configuration from slot 1, leaving it ready for a new module.
2. Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on
the chassis.
3. Remove the module from the packaging.
4. Insert the module into the slot, and slide the module along the card guide until the ejectors on
either side of the module rotate towards the module front panel.
NOTE
When inserting a module in the router, make sure that the module faceplate does not overlap
the faceplate of an adjacent module.
5. Rotate the ejectors flush with the module faceplate. This action will fully seat the module in the
backplane.
6. Tighten the two screws on the module faceplate by pushing them in and turning them
clockwise. Complete the tightening process using the flat-blade screwdriver.
7. Enter the write memory command to ensure that the slot will be correctly configured for the
new module after a reboot.
MLXe-16(config)# write memory
Write startup-config done.
Summary of Contents for PowerConnect B - MLXe 16
Page 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Page 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Page 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Page 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...