The table explains the
View Controller Information
screen details:
Menu Item
Description
PCI ID
Displays the PCI ID.
Physical disk Count
Displays the total number of physical disks available on the system.
Virtual Disk Count
Displays the total number of virtual disks available.
UEFI Driver Version
Displays the UEFI driver version installed on the system.
Firmware Build
Time
Displays the time and date when you last updated the firmware.
Changing the boot order of the virtual disks
Set Bootable Device
allows you to change the boot order of the virtual disk.
1.
Enter the
Dell PERC S130 Configuration Utility
Entering the DELL PERC S130 Configuration Utility
2.
Click
Controller Management
→
Change Controller Properties
.
NOTE: While swapping boot virtual disks, ensure that the boot virtual disks are created from disk drives populated
across slots 0-3 of the system. For information about the disk connectivity for AHCI devices, see
, and for disks slot information, see the system specific Owner's Manual at dell.com/
poweredgemanuals.
3.
Click the link
Set Bootable Device
.
A
Change Order
dialog box displays the list of virtual disks available.
4.
Use the arrow keys to set a virtual disk and
+
or
–
to change the order of the virtual disks that need to be booted first.
5.
Click
Ok
.
The changes to the boot order of the virtual disks are displayed.
Stopping the system from booting if there is a critical BIOS error
Change Controller Properties
screen allows you to either enable or disable the option to stop the system from booting if there is
any critical BIOS error, which requires manual intervention.
1.
Enter the
Dell PERC S130 Configuration Utility
Entering the DELL PERC S130 Configuration Utility
2.
Click
Controller Management
→
Change Controller Properties
.
NOTE: While swapping boot virtual disks, ensure that the boot virtual disks are created from disk drives populated
across slots 0-3 of the system. For information about the disk connectivity for AHCI devices, see
, and for disks slot information, see the system specific Owner's Manual at dell.com/
poweredgemanuals.
3.
You can either enable or disable the
Enable BIOS Stop On Error
.
Converting physical disk to Non-RAID disk
1.
Enter the
Dell PERC S130 Configuration Utility
Entering the DELL PERC S130 Configuration Utility
2.
Click
Controller Management
→
Convert to Non-RAID Disk
.
NOTE: Create boot virtual disk only from disk drives populated across slots 0-3 of the system. For information about
the disk connectivity for AHCI devices, see
Disk connectivity for AHCI devices
, and for disks slot information, see
the system specific Owner's Manual at dell.com/poweredgemanuals.
3.
Select
Select physical disks from slots other than slots 0-3
to enable the selection of the physical disk(s) that are on slot 4
and all slots after.
4.
Select the physical disk(s) and click
OK
.
A confirmation screen is displayed.
27