Error Code
Message Information
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0034
Message
An under voltage fault detected on power supply <
number
>.
Details
This failure may be the result of an electrical issue with cables or
subsystem components in the system.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see
Getting Help
.
PSU0035
Message
An over voltage fault detected on power supply <
number
>.
Action
Check input power or reinstall the power supply. If the issue persists,
see
Getting Help
.
PSU0036
Message
An over current fault detected on power supply <
number
>.
Details
This failure may be the result of an electrical issue with cables or
subsystem components in the system.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see
Getting Help
.
PSU0037
Message
Fan failure detected on power supply <
number
>.
Action
Check for fan blockage. If the problem persists, see
Getting Help
.
PSU0076
Message
A power supply wattage mismatch is detected; power supply
<
number
> is rated for <
value
> watts.
Details
Power supplies should be of the same input type and power rating.
Action
Install matched power supplies and review this manual for proper
configuration.
PSU1201
Message
Power supply redundancy is lost.
118