Error Code
Message Information
Action
Close the chassis and verify hardware inventory. Check system logs.
SEL0006
Message
All event logging is disabled.
Details
This message is displayed when all event logging has been disabled
by the user.
Action
If unintended, re-enable logging.
SEL0008
Message
Log is full.
Details
When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.
Action
Backup and clear log.
SEL0012
Message
Could not create or initialize the system event log.
Details
If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Action
Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.
SEL1204
Message
An unknown system hardware failure detected.
Details
If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Action
Re-configure system to the minimum supported configuration. If
issues persists, contact support.
TMP0118
Message
The system inlet temperature is less than the lower warning
threshold.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0119
Message
The system inlet temperature is less than the lower critical threshold.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.