Error Code
Message Information
MEM8000
Message
Correctable memory error logging disabled for a memory device at
location <
location
>.
Details
Errors are being corrected but no longer logged.
Action
Review system logs for memory exceptions. Reinstall memory at
location <
location
>.
PCI1302
Message
A bus time-out was detected on a component at bus <
bus
>
device<
device
> function <
func
>.
Details
System performance may be degraded. The device has failed to
respond to a transaction.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1304
Message
An I/O channel check error was detected.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1308
Message
A PCI parity error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded, PCI device may fail to
operate, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1320
Message
A bus fatal error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1342
Message
A bus time-out was detected on a component at slot <
number
>.
Details
System performance may be degraded, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1348
Message
A PCI parity error was detected on a component at slot <
number
>.
Details
System performance may be degraded, or system may fail to operate.
115