Icon
Description
Condition
Corrective action
(ePSA). If the hard drives are configured in a
RAID array, restart the system and enter the
host adapter configuration utility program.
Electrical
indicator
The indicator flashes amber
if the system experiences an
electrical error (for example,
voltage out of range, or a
failed power supply unit
(PSU) or voltage regulator).
Check the System Event Log or system
messages for the specific issue. If it is due
to a problem with the PSU, check the LED
on the PSU. Reseat the PSU. If the problem
persists, see the Getting help section.
Temperature
indicator
The indicator flashes amber
if the system experiences a
thermal error (for example,
the ambient temperature is
out of range or fan failure).
Ensure that none of the following
conditions exist:
• A cooling fan has been removed or has
failed.
• System cover, cooling shroud, EMI filler
panel, memory module blank, or back
filler bracket is removed.
• Ambient temperature is too high.
• External airflow is obstructed.
See the Getting help section.
Memory
indicator
The indicator flashes amber
if a memory error occurs.
Check the system event log or system
messages for the location of the failed
memory. Reseat the memory module. If
the problem persists, see the Getting help
section.
Related Links
iDRAC Direct LED indicator codes
The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part
of the iDRAC subsystem.
NOTE: The iDRAC Direct LED indicator does not turn on when the USB port is used in the USB
mode.
18