Configuring jumbo frames is a best practice for both vMotion and vSAN networks, both of which are core components of Cloud
Foundation. All the switch ports on the modular switches and up to the aggregation switches used to connect multiple PowerEdge
MX7000 enclosures together must be configured for jumbo frames. It is also recommended to configure jumbo frames on the VXLAN
network. The validation phase (run as part of the Cloud Foundation installation process) tests end-to-end connectivity of all specified
devices and fail if not correctly configured for jumbo frames.
VLAN and subnets for networking configuration
The following table shows the VLAN and networking data that are used for the Cloud Foundation deployment. In our example, private
addresses are used for Management, vSAN, vMotion, and VXLAN networks. However, this is not mandatory.
Table 10. VLAN and networking data used for the Cloud Foundation deployment
Name
VLAN ID
Subnet
Mask
Default Gateway
Management
1611
172.16.11.0
255.255.255.0
172.16.11.253
vSAN
1612
172.16.12.0
255.255.255.0
172.16.12.253
vMotion
1613
172.16.13.0
255.255.255.0
172.16.13.253
VXLAN
1614
172.16.14.0
255.255.255.0
172.16.14.253
Uplink1
2711
172.17.11.0
255.255.255.0
172.17.11.1
Uplink2
2712
172.17.12.0
255.255.255.0
172.17.12.1
Networking requirements
45
Summary of Contents for PowerEdge MX7000
Page 1: ...Dell EMC VMware Cloud Foundation for PowerEdge MX7000 Deployment Guide ...
Page 8: ...Figure 1 Cloud Foundation deployment workflow 8 Overview ...
Page 27: ...Figure 19 Dual PowerEdge MX7000 enclosure configuration Physical layout 27 ...
Page 29: ...Figure 20 MX9002m Management module cabling Physical layout 29 ...
Page 30: ...Figure 21 Connectivity between FSE modules and FEM modules 30 Physical layout ...
Page 31: ...Figure 22 Uplinks to customer network environment Physical layout 31 ...
Page 42: ...Figure 25 MX9002m Management Module cabling 42 Networking requirements ...
Page 43: ...Figure 26 Connectivity between FSE modules and FEM modules Networking requirements 43 ...
Page 44: ...Figure 27 Uplinks to customer network environment 44 Networking requirements ...